Measures
+ Voltage + Total Current for Capacitive, Inductive,
or Resistive Loads + Power Loss + Power Factor/Tan Delta + Capacitance
+ Inductance | | Options
+ Transformer Leakage Reactance and
Loss + Transformer Turns Ratio + Doble Test Assistant Software DTA
- Embedded Expert System - Apparatus Templates |
| M4000
Doble Test SetÀÇ Æ¯Â¡
1) DC Àý¿¬ÃøÁ¤±â·Î ÃøÁ¤µÇÁö ¾Ê´Â Àý¿¬ºÒ·® ºÎÀ§µµ ÃøÁ¤°¡´É.
2) ±â±â¿îÀüÀ» À§ÇÑ ±â±â ÀüüÀÇ Àý¿¬»óŸ¦ ÆÇ´ÜÇÒ ¼ö ÀÖÀ½. 3) °¢Á¾ Àü±âÀûÀÎ ÃøÁ¤Ä¡·Î Àý¿¬¿È
Ư¼º ¹× ¿îÀü À§Ç輺 µî Æ÷°ýÀûÀÎ ºÐ¼®ÀÌ ¿ëÀÌÇÔ. 4) °¢Á¾ ±â±âº°·Î ÃàÀûµÈ ÃøÁ¤ Data¸¦ ºñ±³ Ȱ¿ëÇÔÀ¸·Î½á Àý¿¬¿È ÆÇ´ÜÀÌ ¿ëÀÌ.
- 1929³â ºÎÅÍ º» Àåºñ¸¦ »ç¿ëÇϰí ÀÖ´Â ¼¼°è °¢ Àü·Âȸ»ç, Á¦ÀÛ»ç·Î ºÎÅÍ ±â±âº°,
typeº°·Î ÃøÁ¤ÇÑ Data¸¦ ¹Þ¾Æ °ü¸® ¹× ºÐ¼®Çϰí ÀÖÀ¸¸ç, °ü·Ã Data¸¦ °í°´¿¡°Ô
Á¦°øÇϰí ÀÖÀ½. * Doble»ç¿¡ ÃàÀûµÈ °¢Á¾ Data´Â °í°´ÇùÀÇü(Client
Conference)¿¡ °¡ÀÔÈÄ È°¿ë°¡´ÉÇÔ.
M4000 Doble Test SetÀÇ Á¤ÀÇ
+ Á¤ÀÇ: Á¤±âÀûÀÎ °¢Á¾ Àü·Â¼³ºñ(º¯¾Ð±â, Â÷´Ü±â, º×½Ì µî)¿¡ 10KVÀÇ
Àü¾ÐÀ» Àΰ¡ÇÏ¿© ÃøÁ¤
´ë»ó±â±âÀÇ Dielectric Loss(Àý¿¬Ã¼ ¼Õ½Ç), Current, Power Factor ¹× Capacitance(ÃæÀü¿ë·®)¸¦
ÃøÁ¤Çϱâ À§ÇÑ ±â±â. Current
¹× Watt-Loss·Î ºÎÅÍ »êÃâµÇ¾îÁø %PFÀÇ º¯µ¿ÃßÀ̸¦ ÃßÀûÇÏ¿© ±â±âÀÇ Àý¿¬¿È¶Ç´Â
ÀÌ»ó¡Èĸ¦ ÆÇ´ÜÇÑ´Ù.
+
±¸Á¶ : - M4100 ÃøÁ¤±â -
M4200 ÄÁÆ®·Ñ·¯¿Í ¼ÒÇÁÆ®¿þ¾î -
Àý¿¬À¯ ½ÃÇè¿ë±â -
High Voltage ÄÉÀÌºí ¹× ½ÃÇèÄÉÀ̺í -
À̵¿¿ë ¼ö·¹ |
M4100
Technical Specifications Power Specifications
Output
Voltage Output Current | 0
to 12 kV 100 mA continuous at 10 kV 200mA for
30 minutes at 10kV 300 mA for 1 minutes at 10 kV | Output
Power | 3
kVA Sinusoidal output signal internal generated in- dependent of input
supply, No loss in per- formance when used with portable generator |
Input Power |
95-132, 190-264 V ac, 47 to 63 Hz 20 A max. at 110 V, 10 A max.
at 220 Autoselectable;no re- configuring hardware required |
Measurement Accuracy and
Range
Test Frequency
| Test
Frequency | | Capacitance | |
| Range: | 45
to 70 Hz | Range: | 0
to 2.7 ¥ìF auto ranging | | Resolution: | 0.1
Hz | Resolution: | 0.1
pF | | Accuracy: | ¡¾
1% of reading | Accuracy: | ¡¾0.5%
of reading, ¡¾1 pF | | Test
Voltage | | Inductance | |
| Range: | 25
to 12 kV | Range: | 0.132
to 1000 kH at 10 kV | | Resolution: | 1
V | Resolution: | 1
¥ìH | | Accuracy: | ¡¾1%
of reading, ¡¾1V | Accuracy: | ¡¾1.5%
of reading | | Test
Current | | Watts | |
| Range: | 0
to 5.0 A auto ranging 0 to 50.0 A when corrected or referred to 10 kV | Range: | 0
to 2kW, actual power 0 to 100kW when corrected or referred to 10kV |
| Resolution: | 0.0001mA
(0.1 ¥ìA) | Resolution: | 0.5
mW | | Accuracy: | ¡¾1%
of reading, ¡¾1¥ìA | Accuracy: | ¡¾2%
of reading at 10 kV ¡¾0.03% of VA, ¡¾0.5 mW | | Power
Factor | | Temperature
Measurement | |
| Range: | 0
to ¡¾100.00% PF 0 to ¡¾200.00% Tan¥ä | Range: | -20¡É
to+50¡É | | Resolution: | 0.01%
PF (0.0001) | Resolution: | 0.1¡É |
| Accuracy: | ¡¾1%
of reading ¡¾0.04% PF/Tan¥ä | Accuracy: | ¡¾4¡É |
|