931A
Power System Analyzer
|
 |
| : Àü·Â°èÅëºÐ¼®±â (3-Phase) |
|
| |
|
|
|
| |
|
931A
ÀÇ Æ¯Â¡
¿ëµµ: Àü¾Ð, Àü·ù, Àü±â·®, °íÁ¶ÆÄ,
À§»ó, Æ®·£µà¼(TD), Timer µîÀ» ÃøÁ¤.
»ç¿ëÀü¾Ð: 110 - 220 V AC ¶Ç´Â Battery (ÀçÃæÀü)
- ¶Ù¾î³ Á¤È®¼ºÀ¸·Î ´Ù¸¥ Àåºñ¿¡ ´ëÇÑ Calibration Àåºñ·Îµµ »ç¿ëµÊ.
* Doble Engineering Company µî.
- °¡º±°í »ç¿ë¹æ¹ýÀÌ °£Æí.
- ÃøÁ¤Ä¡ÀÇ ÀúÀå ¹× Review °¡´É, PC·Î ´Ù¿î·Îµå
 |
Basic
Measurements:
PowerDSA¢â¸¦ ÀÌ¿ëÇÑ
Rms, Phase angle, Frequency, Voltage, Current ¸¦ ÃøÁ¤ÇÑ´Ù.
Accuracy:
Àü¾Ð, Àü·ù: 0.05 %
À§»ó: 0.05 ¡Æ
|
|
|
|
|
|
Power
Quantities
Watts (W), watthours (Wh), volt-amperes (VA), volt-ampere
hours (VAh), volt-amperes reactive (VAR), volt-amperes
reactive hours (VARh), and power factor (PF): PowerDSA¢â
analysis measures them all, with 0.11% basic accuracy.
|
|
Harmonics
total harmonic distortion (THD),
even harmonic distortion (EHD), odd harmonic distortion
(OHD) or K-factor; or as individual harmonic amplitude
and phase.
ch1, ch2 ÀÔ·ÂÀÇ °¢ °íÁ¶ÆÄ Å©±âÇ¥½Ã.
ÃÖ´ë 50Â÷ °íÁ¶ÆÄ±îÁö Ç¥½Ã°¡´É
|
|
|
Waveform
Display
You
can view the signal waveforms for both channels on the
high contrast 240x64 graphic display. Both channels are
normalized to Channel 1 fundamental phase, so you can
see, for example, the relationship between current waveform
distortions and voltage phase.
|
|
Timer
The
Model 931A's timer/counter measures relay operating times
or elapsed test times, or counts input rates and events.
View times in seconds or in terms of power-line cycles.
Both inputs are independently opto-isolated for safety
and flexibility.
|
|
Three-Phase
Measurement
-Basic three-phase display
View voltage, current, phase, frequency and power quantities
on one convenient display.
-Vector display
View voltages, currents and phase angles with their vector
representation.
Voltage/Current Sequence display
View voltage, current and phase along with positive, negative
and zero sequence values.
-Energy display
View voltage, current, phase, frequency and energy quantities
on one convenient display. |
|
|
|
|
|
|
|
Transducer
Calibration
The
outstanding accuracy of the Model 931A with PowerDSA¢â
is ideal for transducer calibration. The Model 931A includes
the necessary dc voltage and current measurements to accurately
measure transducer outputs, using a separate, opto-isolated
input section. With only an external source or load box,
or when making in-service measurements, the Model 931A
provides complete field transducer calibration.
|
|
CT/PT
Ratios
Correction factors for external CTs and/or PTs, can be
entered to display the measured results in input-side
units. You can even measure ratios using the instrument's
CH1/CH2 function. This example shows a nominal 200:1 (or
1000:5) current ratio; if Channel 1 is a CT burden voltage
and Channel 2 CT secondary current, the result is the
loop resistance in ohms.
|
|
Extended
Measurement Ranges
For
greater accuracy, the Model 09311A Auxiliary CT allows
measurement of signals up to 400 amps with total basic
accuracy of 0.1%. This CT mounts directly to the Model
931A, 930A, or 929A current input connectors and may be
used for one two or three of the current inputs, depending
on your needs. |
|
 |
|
|
|